3,516 codes from ABB Robotics · page 19 of 88

34318 · Drive inverter saturated error

ABB Robotics · IRC5 with RobotWare 5, manual revision K

Cause given

34319 · Drive unit critical error

ABB Robotics · IRC5 with RobotWare 5, manual revision K

Cause given

34320 · Too many drive nodes connected

ABB Robotics · IRC5 with RobotWare 5, manual revision K

Cause given

34400 · DC link voltage too high

ABB Robotics · IRC5 with RobotWare 5, manual revision K

Cause given

34401 · DC link voltage too low warning

ABB Robotics · IRC5 with RobotWare 5, manual revision K

Cause given

34402 · DC link voltage too low

ABB Robotics · IRC5 with RobotWare 5, manual revision K

Cause given

34404 · DC link voltage is critically high

ABB Robotics · IRC5 with RobotWare 5, manual revision K

Cause given

34405 · DC link voltage too high warning

ABB Robotics · IRC5 with RobotWare 5, manual revision K

Cause given

34406 · Drive unit power supply error

ABB Robotics · IRC5 with RobotWare 5, manual revision K

Cause given

34407 · Drive unit internal error

ABB Robotics · IRC5 with RobotWare 5, manual revision K

Cause given

34408 · Drive unit hardware data error

ABB Robotics · IRC5 with RobotWare 5, manual revision K

Cause given

34409 · Drive unit startup error

ABB Robotics · IRC5 with RobotWare 5, manual revision K

Cause given

34410 · Too many drive units connected

ABB Robotics · IRC5 with RobotWare 5, manual revision K

Cause given

37001 · Motors ON contactor activation error

ABB Robotics · IRC5 with RobotWare 5, manual revision K

Cause given

37043 · Safety signals overloaded

ABB Robotics · IRC5 with RobotWare 5, manual revision K

Cause given

37044 · Overload on Panel Board digital output signals

ABB Robotics · IRC5 with RobotWare 5, manual revision K

Cause given

37045 · Faulty External Computer fan

ABB Robotics · IRC5 with RobotWare 5, manual revision K

Cause given

37046 · Safety signals overloaded

ABB Robotics · IRC5 with RobotWare 5, manual revision K

Cause given

37049 · Activation contactor activation error

ABB Robotics · IRC5 with RobotWare 5, manual revision K

Cause given

37050 · Overtemperature in main computer

ABB Robotics · IRC5 with RobotWare 5, manual revision K

Cause given

37053 · Low CMOS battery voltage level

ABB Robotics · IRC5 with RobotWare 5, manual revision K

Cause given

37054 · Faulty Computer Unit fan

ABB Robotics · IRC5 with RobotWare 5, manual revision K

Cause given

37056 · Cooling fan error

ABB Robotics · IRC5 with RobotWare 5, manual revision K

37062 · Computer Module power supply warning

ABB Robotics · IRC5 with RobotWare 5, manual revision K

Cause given

37069 · Faulty backup Power Supply

ABB Robotics · IRC5 with RobotWare 5, manual revision K

Cause given

37070 · Overtemp in Control Module Power Supply

ABB Robotics · IRC5 with RobotWare 5, manual revision K

Cause given

37074 · Purge pressure too low

ABB Robotics · IRC5 with RobotWare 5, manual revision K

37075 · Purge pressure too high

ABB Robotics · IRC5 with RobotWare 5, manual revision K

37076 · Unexpected low purge flow

ABB Robotics · IRC5 with RobotWare 5, manual revision K

37077 · Unexpected high purge flow

ABB Robotics · IRC5 with RobotWare 5, manual revision K

37078 · Purge timers differ

ABB Robotics · IRC5 with RobotWare 5, manual revision K

37080 · Purge configuration not valid.

ABB Robotics · IRC5 with RobotWare 5, manual revision K

Cause given

37081 · Purge timers differ

ABB Robotics · IRC5 with RobotWare 5, manual revision K

37082 · Divergence between PIB and MIB outputs

ABB Robotics · IRC5 with RobotWare 5, manual revision K

37090 · Temp. too high, sensor <arg>

ABB Robotics · IRC5 with RobotWare 5, manual revision K

37094 · Activate connection error

ABB Robotics · IRC5 with RobotWare 5, manual revision K

37095 · Brake power fault

ABB Robotics · IRC5 with RobotWare 5, manual revision K

37096 · Brake power fault

ABB Robotics · IRC5 with RobotWare 5, manual revision K

37097 · Brake short circuit fault

ABB Robotics · IRC5 with RobotWare 5, manual revision K

37098 · Brake open circuit fault

ABB Robotics · IRC5 with RobotWare 5, manual revision K

ABB Robotics 34318

Drive inverter saturated error

Cause, as the directory gives them

  • 1) The motor is not properly connected to the drive unit. 2) The motor data in the configuration is not correct. 3) The DC link voltage is too low. 4) Short circuit between motor phases or ground.

From ABB’s own error code directory. The steps to fix it are the maker’s and are on the page linked above, not copied here.