Error codes

What a robot’s error code means, from the maker’s own directory, with a link to the page where the maker says what to do about it.

Type the code from the teach pendant, or words from the message. Each directory is grouped the way the maker prints it: by robot generation, then by section.

Clear

483 codes from Universal Robots · page 7 of 13

C163A4 · Wrist 2 joint. Something is wrong in the application. Recurring protective stops should be resolved, ignoring it can void warranty.

Universal Robots · CB3 and Earlier Models

C163 More than 50 Protective Stops are detected on the same joint within 8 hours of operation.Cause given

C163A5 · Wrist 3 joint. Something is wrong in the application. Recurring protective stops should be resolved, ignoring it can void warranty.

Universal Robots · CB3 and Earlier Models

C163 More than 50 Protective Stops are detected on the same joint within 8 hours of operation.Cause given

C164A0 · Wrist 1 is too close to safety plane

Universal Robots · CB3 and Earlier Models

C164 Wrist position close to safety plane limits

C164A1 · Wrist 2 is too close to safety plane

Universal Robots · CB3 and Earlier Models

C164 Wrist position close to safety plane limits

C164A2 · Wrist 3 is too close to safety plane

Universal Robots · CB3 and Earlier Models

C164 Wrist position close to safety plane limits

C171A0 · A MoveC-Waypoint were skipped due to a blend.

Universal Robots · CB3 and Earlier Models

C171 Issue with blends

C171A1 · Blend radius too small in a MoveC

Universal Robots · CB3 and Earlier Models

C171 Issue with blends

C171A3 · A ServoC-Waypoint were skipped due to a blend.

Universal Robots · CB3 and Earlier Models

C171 Issue with blendsCause given

C171A4 · Overlapping Blends in a MoveJ, a Waypoint was skipped

Universal Robots · CB3 and Earlier Models

C171 Issue with blends

C171A5 · Overlapping Blends in a MoveJ, a Waypoint was skipped

Universal Robots · CB3 and Earlier Models

C171 Issue with blends

C171A6 · Overlapping Blends in a MoveJ, a Waypoint was skipped

Universal Robots · CB3 and Earlier Models

C171 Issue with blends

C171A7 · Overlapping Blends in a MoveJ, a Waypoint was skipped

Universal Robots · CB3 and Earlier Models

C171 Issue with blends

C171A9 · A MoveP-Waypoint were skipped due to a blend.

Universal Robots · CB3 and Earlier Models

C171 Issue with blendsCause given

C171A10 · Blend radius too small error in a MoveP

Universal Robots · CB3 and Earlier Models

C171 Issue with blends

C171A11 · Overlapping Blends in a MoveL, a Waypoint was skipped

Universal Robots · CB3 and Earlier Models

C171 Issue with blends

C171A12 · Overlapping Blends in a MoveL, a Waypoint was skipped

Universal Robots · CB3 and Earlier Models

C171 Issue with blends

C171A13 · Overlapping Blends in a MoveL, a Waypoint was skipped

Universal Robots · CB3 and Earlier Models

C171 Issue with blends

C171A14 · Overlapping Blends in a MoveL, a Waypoint was skipped

Universal Robots · CB3 and Earlier Models

C171 Issue with blends

C173A0 · Base.

Universal Robots · CB3 and Earlier Models

C173 Robot motion causes too high joint torques

C173A1 · Shoulder.

Universal Robots · CB3 and Earlier Models

C173 Robot motion causes too high joint torques

C173A2 · Elbow.

Universal Robots · CB3 and Earlier Models

C173 Robot motion causes too high joint torques

C173A3 · Wrist 1.

Universal Robots · CB3 and Earlier Models

C173 Robot motion causes too high joint torques

C173A4 · Wrist 2.

Universal Robots · CB3 and Earlier Models

C173 Robot motion causes too high joint torques

C173A5 · Wrist 3.

Universal Robots · CB3 and Earlier Models

C173 Robot motion causes too high joint torques

C173A6 · Base. Problem identified when executing program line {unsigned}.

Universal Robots · CB3 and Earlier Models

C173 Robot motion causes too high joint torques

C173A7 · Shoulder. Problem identified when executing program line {unsigned}.

Universal Robots · CB3 and Earlier Models

C173 Robot motion causes too high joint torques

C173A8 · Elbow. Problem identified when executing program line {unsigned}.

Universal Robots · CB3 and Earlier Models

C173 Robot motion causes too high joint torques

C173A9 · Wrist 1. Problem identified when executing program line {unsigned}.

Universal Robots · CB3 and Earlier Models

C173 Robot motion causes too high joint torques

C173A10 · Wrist 2. Problem identified when executing program line {unsigned}.

Universal Robots · CB3 and Earlier Models

C173 Robot motion causes too high joint torques

C173A11 · Wrist 3. Problem identified when executing program line {unsigned}.

Universal Robots · CB3 and Earlier Models

C173 Robot motion causes too high joint torques

C174A0 · Base.

Universal Robots · CB3 and Earlier Models

C174 Robot motion causes too high jump in joint torques

C174A1 · Shoulder.

Universal Robots · CB3 and Earlier Models

C174 Robot motion causes too high jump in joint torques

C174A2 · Elbow.

Universal Robots · CB3 and Earlier Models

C174 Robot motion causes too high jump in joint torques

C174A3 · Wrist 1.

Universal Robots · CB3 and Earlier Models

C174 Robot motion causes too high jump in joint torques

C174A4 · Wrist 2.

Universal Robots · CB3 and Earlier Models

C174 Robot motion causes too high jump in joint torques

C174A5 · Wrist 3.

Universal Robots · CB3 and Earlier Models

C174 Robot motion causes too high jump in joint torques

C174A6 · Base. Problem identified when executing program line {unsigned}.

Universal Robots · CB3 and Earlier Models

C174 Robot motion causes too high jump in joint torques

C174A7 · Shoulder. Problem identified when executing program line {unsigned}.

Universal Robots · CB3 and Earlier Models

C174 Robot motion causes too high jump in joint torques

C174A8 · Elbow. Problem identified when executing program line {unsigned}.

Universal Robots · CB3 and Earlier Models

C174 Robot motion causes too high jump in joint torques

C174A9 · Wrist 1. Problem identified when executing program line {unsigned}.

Universal Robots · CB3 and Earlier Models

C174 Robot motion causes too high jump in joint torques

Universal Robots C163A4

Wrist 2 joint. Something is wrong in the application. Recurring protective stops should be resolved, ignoring it can void warranty.

Cause, as the directory gives them

  • Frequent protective stops is an indication of either an error in the application, or a hardware failure in a joint.

From Universal Robots’s own error code directory. The steps to fix it are the maker’s and are on the page linked above, not copied here.