4,739 codes · page 99 of 119

C195A3 · for momentum safety limit

Universal Robots · CB3 and Earlier Models

C195 Conveyor speed too high

C200A1 · Hardware ID is wrong

Universal Robots · CB3 and Earlier Models

C200 Safety Control Board hardware error

C200A2 · MCU type is wrong

Universal Robots · CB3 and Earlier Models

C200 Safety Control Board hardware errorCause given

C200A3 · Part ID is wrong

Universal Robots · CB3 and Earlier Models

C200 Safety Control Board hardware errorCause given

C200A4 · RAM test failed

Universal Robots · CB3 and Earlier Models

C200 Safety Control Board hardware errorCause given

C200A5 · Register test failed

Universal Robots · CB3 and Earlier Models

C200 Safety Control Board hardware errorCause given

C200A6 · pRom Crc test failed

Universal Robots · CB3 and Earlier Models

C200 Safety Control Board hardware errorCause given

C200A7 · Watchdog reset the processor

Universal Robots · CB3 and Earlier Models

C200 Safety Control Board hardware errorCause given

C200A8 · OVG signal test not passed

Universal Robots · CB3 and Earlier Models

C200 Safety Control Board hardware errorCause given

C200A9 · 3V3A power good pin is low

Universal Robots · CB3 and Earlier Models

C200 Safety Control Board hardware errorCause given

C200A10 · 3V3B power good pin is low

Universal Robots · CB3 and Earlier Models

C200 Safety Control Board hardware errorCause given

C200A11 · 5V power good is low

Universal Robots · CB3 and Earlier Models

C200 Safety Control Board hardware errorCause given

C200A12 · 3V3 voltage too low

Universal Robots · CB3 and Earlier Models

C200 Safety Control Board hardware errorCause given

C200A13 · 3v3 voltage too high

Universal Robots · CB3 and Earlier Models

C200 Safety Control Board hardware errorCause given

C200A14 · 48V input is too low

Universal Robots · CB3 and Earlier Models

C200 Safety Control Board hardware error

C200A15 · 48V input is too high

Universal Robots · CB3 and Earlier Models

C200 Safety Control Board hardware error

C200A16 · 24V IO short circuited

Universal Robots · CB3 and Earlier Models

C200 Safety Control Board hardware errorCause given

C200A17 · PC current is too high

Universal Robots · CB3 and Earlier Models

C200 Safety Control Board hardware error

C200A18 · Robot voltage is too low

Universal Robots · CB3 and Earlier Models

C200 Safety Control Board hardware error

C200A19 · Robot voltage is too high

Universal Robots · CB3 and Earlier Models

C200 Safety Control Board hardware error

C200A20 · 24V IO voltage is too low

Universal Robots · CB3 and Earlier Models

C200 Safety Control Board hardware error

C200A21 · 12V voltage is too high

Universal Robots · CB3 and Earlier Models

C200 Safety Control Board hardware error

C200A22 · 12V voltage is too low

Universal Robots · CB3 and Earlier Models

C200 Safety Control Board hardware error

C200A23 · It took too long to stabilize 24V

Universal Robots · CB3 and Earlier Models

C200 Safety Control Board hardware error

C200A24 · It took too long to stabilize 24V IO

Universal Robots · CB3 and Earlier Models

C200 Safety Control Board hardware error

C200A25 · 24V voltage is too high

Universal Robots · CB3 and Earlier Models

C200 Safety Control Board hardware error

C200A26 · 24V IO voltage is too high

Universal Robots · CB3 and Earlier Models

C200 Safety Control Board hardware error

C201A0 · Setup of Safety Control Board failed

Universal Robots · CB3 and Earlier Models

C201 Setup of Safety Control Board failedCause given

C201A1 · SCB uA is not responding

Universal Robots · CB3 and Earlier Models

C201 Setup of Safety Control Board failedCause given

C201A2 · SCB uB is not responding

Universal Robots · CB3 and Earlier Models

C201 Setup of Safety Control Board failedCause given

C201A3 · SCB is not responding

Universal Robots · CB3 and Earlier Models

C201 Setup of Safety Control Board failedCause given

C204A1 · Sudden change in target position

Universal Robots · CB3 and Earlier Models

C204 Path sanity check failed

C204A2 · Inconsistency between target position and speed

Universal Robots · CB3 and Earlier Models

C204 Path sanity check failed

C204A3 · Sudden stop

Universal Robots · CB3 and Earlier Models

C204 Path sanity check failedCause given

C204A4 · Robot has not stopped in the allowed reaction and braking time

Universal Robots · CB3 and Earlier Models

C204 Path sanity check failed

C204A5 · Robot program resulted in invalid setpoint

Universal Robots · CB3 and Earlier Models

C204 Path sanity check failed

C204A6 · Blending failed and resulted in an invalid setpoint

Universal Robots · CB3 and Earlier Models

C204 Path sanity check failed

C204A7 · Robot approaching singularity - Acceleration threshold failed

Universal Robots · CB3 and Earlier Models

C204 Path sanity check failed

C205A0 · Inconsistency between target position and speed

Universal Robots · CB3 and Earlier Models

C205 Target speed does not match target position

C206A0 · Target joint speed does not match target joint position change - Base

Universal Robots · CB3 and Earlier Models

C206 Sanity check failed