Error codes

What a robot’s error code means, from the maker’s own directory, with a link to the page where the maker says what to do about it.

Type the code from the teach pendant, or words from the message. Each directory is grouped the way the maker prints it: by robot generation, then by section.

4,739 codes · page 112 of 119

C338A8 · The robot rejected the PROFIsafe F-Parameter set

Universal Robots · e-Series and Later Models

C338 PROFIsafeCause given

C338A11 · An iPar CRC mismatch has been detected

Universal Robots · e-Series and Later Models

C338 PROFIsafeCause given

C338A12 · An error occured during PROFIsafe communication

Universal Robots · e-Series and Later Models

C338 PROFIsafeCause given

C338A13 · The PROFIsafe watchdog timed out

Universal Robots · e-Series and Later Models

C338 PROFIsafeCause given

C338A14 · The PROFInet provider status is bad

Universal Robots · e-Series and Later Models

C338 PROFIsafeCause given

C338A17 · Destination address mismatch

Universal Robots · e-Series and Later Models

C338 PROFIsafeCause given

C338A18 · Destination address invalid

Universal Robots · e-Series and Later Models

C338 PROFIsafeCause given

C338A19 · Source address mismatch

Universal Robots · e-Series and Later Models

C338 PROFIsafeCause given

C338A20 · Source address invalid

Universal Robots · e-Series and Later Models

C338 PROFIsafeCause given

C338A21 · Wrong PROFIsafe submodule selected

Universal Robots · e-Series and Later Models

C338 PROFIsafeCause given

C339A0 · Critical error

Universal Robots · e-Series and Later Models

C339 Cross communication

C340A0 · Idle power consumption too high

Universal Robots · e-Series and Later Models

C340 Energy MonitoringCause given

C340A1 · Energy surplus shutdown

Universal Robots · e-Series and Later Models

C340 Energy MonitoringCause given

C340A2 · Energy burst period exceeded, average power: {float}W

Universal Robots · e-Series and Later Models

C340 Energy MonitoringCause given

C340A3 · The Energy Removal Device peak power exceeded

Universal Robots · e-Series and Later Models

C340 Energy MonitoringCause given

C340A4 · The Energy Removal Device drew too much power over a period

Universal Robots · e-Series and Later Models

C340 Energy MonitoringCause given

C341A0 · Critical error

Universal Robots · e-Series and Later Models

C341 Motor encoderCause given

C341A9 · The scheduled motor encoder SPI package transfer did not complete before the deadline.

Universal Robots · e-Series and Later Models

C341 Motor encoderCause given

C341A10 · CRC error in CH0 transfer, frame: {hex}

Universal Robots · e-Series and Later Models

C341 Motor encoderCause given

C341A22 · Detailed status error: Signal clipping, strong external magnetic field is present.

Universal Robots · e-Series and Later Models

C341 Motor encoderCause given

C341A23 · Detailed status warning: Signal amplitude too high. The read head is too close to the ring.

Universal Robots · e-Series and Later Models

C341 Motor encoderCause given

C341A24 · Detailed status error: ASIC was reset, external RFI glitch caused encoder to reset.

Universal Robots · e-Series and Later Models

C341 Motor encoderCause given

C341A25 · Detailed status error: ASIC synchronization lost, external RFI glitch caused malfunction.

Universal Robots · e-Series and Later Models

C341 Motor encoderCause given

C341A26 · Detailed status error: Encoder not configured properly.

Universal Robots · e-Series and Later Models

C341 Motor encoderCause given

C341A27 · Detailed status warning: Signal amplitude low. The distance between the read head and the ring is too large.

Universal Robots · e-Series and Later Models

C341 Motor encoderCause given

C341A28 · Detailed status error: Signal lost. The read head is out of alignment with the ring or the ring is damaged.

Universal Robots · e-Series and Later Models

C341 Motor encoderCause given

C341A30 · Detailed status error: Power supply error. The read head power supply voltage is out of specified range.

Universal Robots · e-Series and Later Models

C341 Motor encoderCause given

C341A31 · Detailed status error: System error. Malfunction inside the circuitry or inconsistent calibration data is detected.

Universal Robots · e-Series and Later Models

C341 Motor encoderCause given

C341A32 · Detailed status error: Magnetic pattern error. A stray magnetic field is present or metal particles are present between the read head and the ring or radial positioning

Universal Robots · e-Series and Later Models

C341 Motor encoderCause given

C341A33 · Detailed status error: Acceleration to high.

Universal Robots · e-Series and Later Models

C341 Motor encoderCause given

C341A65 · Latest parsed motor encoder position was too old.

Universal Robots · e-Series and Later Models

C341 Motor encoderCause given

C341A86 · An error occured while reading the encoder firmware version.

Universal Robots · e-Series and Later Models

C341 Motor encoderCause given

C341A87 · The encoder firmware version is not valid.

Universal Robots · e-Series and Later Models

C341 Motor encoderCause given

C341A88 · A reading of the register {hex} was attempted which is not valid for the present encoder

Universal Robots · e-Series and Later Models

C341 Motor encoder

C341A89 · A write of the register {hex} was attempted which is not valid for the present encoder

Universal Robots · e-Series and Later Models

C341 Motor encoderCause given

C341A90 · Tried to access register {hex}, which is not valid for the present encoder

Universal Robots · e-Series and Later Models

C341 Motor encoderCause given

C341A92 · The encoder reported that it has not performed a self-calibration

Universal Robots · e-Series and Later Models

C341 Motor encoderCause given

C341A95 · Detailed status error: System error. Malfunction inside the circuitry.

Universal Robots · e-Series and Later Models

C341 Motor encoderCause given

C341A96 · Detailed status error: System error. Inconsistent calibration data detected.

Universal Robots · e-Series and Later Models

C341 Motor encoderCause given

C342A0 · Module initialization error

Universal Robots · e-Series and Later Models

C342 Motor ParametersCause given